Q. Where can I find information about shear reinforcement for beam-column connections in intermediate moment frames? A. Section 18.4.4 of AACI 318-19 includes earthquake resistance requirements for joints in intermediate moment frames. You may wish to refer to ACI 352R, “Recommendations for Design of Beam-Column Connections in Monolithic Reinforced Concrete Structures,” for additional information on vertical joint reinforcement. References: ACI 318-19; ACI 352R-02 Topics in Concrete: 318 Building Code; Design; Joints, Structural; Shear
Q. Where can I find information about shear reinforcement for beam-column connections in intermediate moment frames?
A. Section 18.4.4 of AACI 318-19 includes earthquake resistance requirements for joints in intermediate moment frames. You may wish to refer to ACI 352R, “Recommendations for Design of Beam-Column Connections in Monolithic Reinforced Concrete Structures,” for additional information on vertical joint reinforcement.
References: ACI 318-19; ACI 352R-02
Topics in Concrete: 318 Building Code; Design; Joints, Structural; Shear