ABOUT THE INTERNATIONAL CONCRETE ABSTRACTS PORTAL

  • The International Concrete Abstracts Portal is an ACI led collaboration with leading technical organizations from within the international concrete industry and offers the most comprehensive collection of published concrete abstracts.

International Concrete Abstracts Portal

  


Title: Critical Corrosion Amount to Cause Cracking of Reinforced Concrete Structures

Author(s): Byung Hwan Oh, Ki Hyun Kim, and Bong Seok Jang

Publication: Materials Journal

Volume: 106

Issue: 4

Appears on pages(s): 333-339

Keywords: corrosion; cover; crack; durability; strength; test.

DOI: 10.14359/56653

Date: 7/1/2009

Abstract:
The corrosion of a steel bar in concrete induces expansion pressure and thus causes tensile stresses in surrounding concrete. This may cause serious cracking in concrete cover, which greatly affects the serviceability and durability of concrete structures. Therefore, it is necessary to realistically determine the critical corrosion amount (CCA) that causes the initiation of cracking in concrete cover. The purpose of this study is to explore and determine the CCA that causes surface cracking of concrete cover. To this end, a comprehensive experimental study was conducted. Major test variables include concrete strength and cover thickness. The corrosion tests of steel bar in concrete have been conducted, and the strains on the surface of concrete cover have been measured according to various amounts of steel corrosion. The CCA, which causes the initiation of cracking on the surface of concrete cover, was determined from the present test results. It was seen that CCA increases greatly with an increase of cover thickness of concrete. The present study indicates that CCA increases approximately proportionally to the square of concrete cover thickness. The concrete strength also affects CCA. It can be seen from this study that CCA increases with an increase of compressive strength, especially in the case of normally used medium and large cover thicknesses, that is, for a cover thickness above 40 mm (1.6 in.) in actual concrete structures. It was found, however, that the effect of the compressive strength on CCA is not large for small cover thickness such as 20 mm (0.8 in.). The present study may provide a good base for future development of realistic durability design and service-life assessment of concrete structures.


ALSO AVAILABLE IN:

Electronic Materials Journal