International Concrete Abstracts Portal

  


Title: Parking Structure Damage

Author(s): Scott M. Adan and René W. Luft

Publication: Concrete International

Volume: 31

Issue: 10

Appears on pages(s): 29-32

Keywords: assessment, external post-tensioning, reseating, anchorage.

DOI:

Date: 10/1/2009

Abstract:
The authors were contracted to evaluate a severely damaged parking garage in Northern California. The structure’s slab exhibited extensive cracking, visible deflections, and a partially collapsed area, indicating a one-time overload. Detailed assessment included the use of ground-penetrating radar surveys to locate reinforcing bars and strands as well as tests of core samples to determine the concrete properties. Repairs included selective replacement of damaged slabs, epoxy injection of cracks, installation of external post-tensioning tendons, and reseating of the existing tendons to a higher tension level. The excessive slab deflections were removed and the structure was restored to service.




  


ABOUT THE INTERNATIONAL CONCRETE ABSTRACTS PORTAL

  • The International Concrete Abstracts Portal is an ACI led collaboration with leading technical organizations from within the international concrete industry and offers the most comprehensive collection of published concrete abstracts.