Prepublished: Effect of Staggering Distances on the Splice Strength of New-Generation GFRP Reinforcing Bars

International Concrete Abstracts Portal

  


Title: Prepublished: Effect of Staggering Distances on the Splice Strength of New-Generation GFRP Reinforcing Bars

Author(s): Seyed Arman Hosseini, Ahmed Sabry Farghaly, Abolfazl Eslami, and Brahim Benmokrane

Publication: Structural Journal

Volume:

Issue:

Appears on pages(s):

Keywords: concrete structures; bond strength; design codes; development length; GFRP reinforcing bars; lap splicing; splice length; splice strength; staggering effect

DOI: 10.14359/51745640

Date: 2/11/2025

Abstract:
This study addressed a critical knowledge gap by examining the influence of staggering on the bond strength of lapped glass fiber-reinforced polymer (GFRP) bars in concrete members. It involved a comprehensive investigation of new-generation GFRP bars with varying staggering configurations in nine large-scale GFRP-RC beams with a rectangular cross-section of 300 mm × 450 mm and a length of 5,200 mm. The tests investigated splice strength with three staggering distances: 0, 1.0, and 1.3 times the splice length (ls) from the center-to-center of two adjacent splices, and three splice lengths of 28, 38, and 45 times the bar diameter (db). Results revealed a slight improvement in ultimate load-carrying capacity (less than 10%) for partially and fully staggered splices compared to non-staggered ones, with the latter exhibiting a more ductile failure mode. The effect of staggering was consistent across different splice lengths, demonstrating that splice length was not a factor. Although staggering reduced flexural crack width, it increased the total number of cracks due to expanded splice regions. Bond strength improved with staggering, with gains of 4.0% and 8.0% for partially and fully staggered splices, respectively. ACI 440.11-22 provides more accurate predictions of the bond strength of lap-spliced GFRP bars than the other design codes showing an average test-to-prediction ratio of 1.03 for non-staggered splices. Nevertheless, it requires some reconsideration when it comes to staggered splices. To address this, a proposed modification factor was introduced to account for staggering conditions when calculating bond strength and splice length in ACI 440.11-22.


ALSO AVAILABLE IN:

Electronic Structural Journal



  


ABOUT THE INTERNATIONAL CONCRETE ABSTRACTS PORTAL

  • The International Concrete Abstracts Portal is an ACI led collaboration with leading technical organizations from within the international concrete industry and offers the most comprehensive collection of published concrete abstracts.

Edit Module Settings to define Page Content Reviewer