Abstract:
Brittle punching failure of flat plates can occur due to the transfer of shearing forces and unbalanced moments between slabs and columns. Design of connections of columns to flat plates to insure safety against punching failure is presented. This paper covers the design procedure in most practical situations, including interior, edge, and corner columns; prestressed and nonprestressed slabs; slabs with openings; and slabs with shear reinforcement. The ACI 318-95 Building Code requirements are adhered to where applicable. Numerical examples are presented to demonstrate the design procedure. Seismic design considerations are not discussed in this paper.