Title:
Transfer Girder with Asymmetric Loading
Author(s):
Adam S. Lubell and Katrin Habel
Publication:
Symposium Paper
Volume:
273
Issue:
Appears on pages(s):
1-20
Keywords:
DOI:
10.14359/51682294
Date:
9/20/2010
Abstract:
A transfer girder with 18’-8” (5690 mm) span is designed to provide column-free space in a hotel conference room at the second floor. The girder is subject to a tributary area load from the third floor and a terminated column which is offset from the mid-span location. All analysis and design is completed in accordance with Appendix A of ACI 318-08. Preliminary designs are examined for two alternate truss models that differ primarily in the slope of the inclined web members. For the preferred option, a detailed design is completed including direct consideration of fan-shaped struts at the column locations. The detailed design is also compared against the reinforcement requirements from the sectional design provisions of ACI 318-08.