Strength of Interface Shear Reinforcement with Limited Development Length

International Concrete Abstracts Portal

The International Concrete Abstracts Portal is an ACI led collaboration with leading technical organizations from within the international concrete industry and offers the most comprehensive collection of published concrete abstracts.

  


Title: Strength of Interface Shear Reinforcement with Limited Development Length

Author(s): Regina N. Waweru, Guillermo Palacios, and Shih-Ho Chao

Publication: Structural Journal

Volume: 115

Issue: 4

Appears on pages(s): 983-996

Keywords: box beam; composite beam; development length; embedded length; interface shear; pullout test; push-off test; shear friction; slab beam

DOI: 10.14359/51702061

Date: 7/1/2018

Abstract:
The ability of a composite beam to act as a monolithic member relies heavily on the bond between the precast beam and the cast-in-place (CIP) slab. Insufficient anchorage of the interface reinforcement could lead to direct pullout due to localized fracture of the surrounding concrete, thereby failing to develop the reinforcement’s yield stress. The short embedded length of approximately 2 in. (50.8 mm) used for interface shear reinforcement is a common practice for the box and slab bridge beams in 70% of the states in the United States. In this study, 18 push-off specimens were tested to evaluate the effect of clamping action of reinforcement on the friction component of the interface (or “horizontal”) shear capacity. In addition, 24 pullout specimens were tested to evaluate the effect of width and bend angle on the pullout strength of interface shear reinforcement. The tests conducted in this research indicated that the American Association of State Highway and Transportation Officials (AASHTO) equation used to account for interface shear in composite concrete beams can overestimate the contribution of the interface shear reinforcement to the friction force for composite beams with a short embedded length less than 4 in. (101.6 mm). Experimental results indicate that, while the clamping force is considerably lower for short embedded length, the presence of the reinforcement effectively engages the concrete in the CIP slab, which enhances the interlocking action and, hence, the overall shear resistance. A modification to the current AASHTO equation is proposed to provide more accurate estimation of the friction force from interface shear reinforcement with a short embedded length.

Related References:

AASHTO, 2014, “LRFD Bridge Design Specifications,” seventh edition, American Association of State Highway and Transportation Officials (AASHTO), Washington, DC, 1704 pp.

ACI Committee 318, 2014, “Building Code Requirements for Structural Concrete (ACI 318-14) and Commentary (ACI 318R-14),” American Concrete Institute, Farmington Hills, MI, 520 pp.

Ali, M. A., and White, R. N., 1999, “Enhanced Contact Model for Shear Friction of Normal and High-Strength Concrete,” ACI Structural Journal, V. 96, No. 3, May-June, pp. 348-360.

Bass, R. A.; Carrasquillo, R. L.; and Jirsa, J. O., 1989, “Shear Transfer across New and Existing Concrete Interfaces,” ACI Structural Journal, V. 86, No. 4, July-Aug., pp. 383-393.

Birkeland, P. W., and Birkeland, H. W., 1966, “Connections in Precast Concrete Construction,” ACI Journal Proceedings, V. 63, No. 3, Mar., pp. 345-368.

Hanson, N. W., 1960, “Precast-Prestressed Concrete Bridges – 2. Horizontal Shear Connections,” Journal PCA Research and Development Laboratories, V. 2, No. 2, pp. 38-58; also PCA Development Department Bulletin D35, 1960, 21 pp.

Harries, K. A.; Zeno, G. A.; and Shahrooz, B., 2012, “Toward an Improved Understanding of Shear-Friction Behavior,” ACI Structural Journal, V. 109, No. 6, Nov.-Dec., pp. 835-844.

Hofbeck, J. A.; Ibrahim, I. O.; and Mattock, A. H., 1969, “Shear Transfer in Reinforced Concrete,” ACI Journal Proceedings, V. 66, No. 2, Feb., pp. 119-128.

Kahn, L. F., and Mitchell, A. D., 2002, “Shear Friction Tests with High-Strength Concrete,” ACI Structural Journal, V. 99, No. 1, Jan.-Feb., pp. 98-103.

Marques, J. L. G., and Jirsa, J. O., 1975, “A Study of Hooked Bar Anchorages in Beam-Column Joints,” ACI Journal Proceedings, V. 72, No. 5, May, pp. 198-209.

Mattock, A. H., 1987, “Anchorage of Stirrups in a Thin Cast-in-Place Topping,” PCI Journal, V. 32, No. 6, pp. 70-85. doi: 10.15554/pcij.11011987.70.85

Mattock, A. H., and Hawkins, N. M., 1972, “Shear Transfer in Reinforced Concrete— Recent Research,” PCI Journal, V. 17, No. 2, pp. 55-75. doi: 10.15554/pcij.03011972.55.75

Palacios, G., 2015, “Performance of Full-Scale Ultra-High Performance Fiber-Reinforced Concrete Column Subjected to Extreme Earthquake-Type Loading and Effect of Surface Preparation on the Cohesion and Friction Factors of the AASHTO Interface Shear Equation,” master’s thesis, Department of Civil Engineering, University of Texas at Arlington, Arlington, TX, 625 pp.

Park, P., and Paulay, T., 1975, Reinforced Concrete Structures, John Wiley & Sons, Inc., New York, 769 pp.

Paulay, T., and Loeber, P. J., 1974, “Shear Transfer by Aggregate Interlock,” Shear in Reinforced Concrete, SP-42, American Concrete Institute, Farmington Hills, MI, pp. 1-15.

Paulay, T.; Park, R.; and Phillips, M. H., 1974, “Horizontal Construction Joints in Cast in Place Reinforced Concrete,” Shear in Reinforced Concrete, SP-42, American Concrete Institute, Farmington Hills, MI, pp. 599-616.

Rehm, G., 1969, “Criteria for Evaluation of Reinforcement bars with High Quality Composite, Reinforced Concrete,” Reports from Research and Practice, Wilhelm Ernst & Sohn, Berlin, Germany, pp. 79-96.

Santos, P. M. D., and Júlio, E. N. B. S., 2014, “Interface Shear Transfer on Composite Concrete Members,” ACI Structural Journal, V. 111, No. 1, Jan.-Feb., pp. 113-122.

Scholz, D. P., 2004, “Performance Criteria Recommendations for Mortars used in Full-Depth Precast Concrete Bridge Deck Panels Systems,” master’s thesis, Virginia Polytechnic Institute and State University, Blacksburg, VA, 101 pp.

Texas Department of Transportation (TxDOT), 2014, “Standard Specifications for Construction and Maintenance of Highways, Streets, and Bridges,” Nov., Austin, TX, 919 pp.

Walraven, J.; Frenay, J.; and Pruijssers, A., 1987, “Influence of Concrete Strength and Load History on the Shear Friction Capacity of Concrete Members,” PCI Journal, V. 32, No. 1, pp. 66-84. doi: 10.15554/pcij.01011987.66.84

Waweru, R. N., 2015, “Strength of Horizontal Shear Reinforcement with Limited Development,” PhD dissertation, University of Texas at Arlington, Arlington, TX, 305 pp.

Wight, J. K., 2016, Reinforced Concrete—Mechanics and Design, seventh edition, Pearson Education Inc., Hoboken, NJ, 1144 pp.