International Concrete Abstracts Portal

Showing 1-5 of 23 Abstracts search results

Document: 

CI4612ConcreteQA

Date: 

December 1, 2024

Publication:

Concrete International

Volume:

46

Issue:

12

Abstract:

This Q&A focuses on comparison of a level straightedge used when performing ASTM E1155 or ASTM E1486 testing versus a manual straightedge used in the manual straightedge method described in ACI 117-10(15). Additional information on requirements related to performing the manual straightedge method is also provided.


Document: 

CI4503Q&A

Date: 

March 1, 2023

Author(s):

Bruce A. Suprenant and Jim Klinger

Publication:

Concrete International

Volume:

45

Issue:

3

Abstract:

This month’s Q&A discusses a disagreement between a subcontractor and a general contractor (GC) on tolerances governing concrete work on the project. While the subcontractor believes that 1 in. tolerances in ACI 117-10(15) for horizontal deviations for edge-of-slab location and column location apply, the GC insists on a zero-tolerance condition illustrated in a detail drawing.


Document: 

CI4409Zhang

Date: 

September 1, 2022

Author(s):

Lingfeng (Leo) Zhang, James Klinger, and Bruce A. Suprenant

Publication:

Concrete International

Volume:

44

Issue:

9

Abstract:

In December 2021, the American Society of Concrete Contractors (ASCC) initiated a study focused on laser scanning results and deliverables for slabs-on-ground to provide recommendation to Joint ACI-ASCC Committee 117, Tolerances. The article discusses slab thickness and F-numbers results from this study, possible issues with laser scan results, and provides recommendations for organization and presentation of laser scan results for a slab-on-ground.


Document: 

CI4407ZhangA

Date: 

July 1, 2022

Author(s):

Lingfeng (Leo) Zhang, James Klinger, and Bruce A. Suprenant

Publication:

Concrete International

Volume:

44

Issue:

7

Abstract:

ACI 117-10(15) provides tolerances for core test and impact-echo thickness measurements. These measurement techniques as well as laser scanning and ground-penetrating radar were used to collect thickness data from a slab-on-ground test panel. The data was then analyzed to determine appropriate average and individual thickness tolerances for all these test methods.


Document: 

CI4307Tipping

Date: 

July 1, 2021

Author(s):

Eldon Tipping, Tim Manherz, Paul J. Beagley, Peter J. Ruttura, and Bruce A. Suprenant

Publication:

Concrete International

Volume:

43

Issue:

7

Abstract:

Members of ACI Committee 330 have questioned the applicability of ACI 117-10(15) tolerances for concrete slabs-on-ground (typically interior slabs with horizontal top and bottom surfaces) for sloped slabs-on-ground. The article discusses thickness variations evaluated for 32 slab-on-ground parking lot pavement placements. Based on the data, the authors propose thickness tolerances for adoption by Joint ACI-ASCC Committee 117 and ACI Committee 330.


12345

Results Per Page 





ABOUT THE INTERNATIONAL CONCRETE ABSTRACTS PORTAL

  • The International Concrete Abstracts Portal is an ACI led collaboration with leading technical organizations from within the international concrete industry and offers the most comprehensive collection of published concrete abstracts.

Edit Module Settings to define Page Content Reviewer