International Concrete Abstracts Portal

Showing 1-5 of 329 Abstracts search results

Document: 

CI4702ConcreteQA

Date: 

February 1, 2025

Publication:

Concrete International

Volume:

47

Issue:

2

Abstract:

Should concrete core samples extracted from a structure be submerged in water until testing? This month’s Q&A provides answer to that question along with a discussion on proper and improper moisture conditioning of cores to be tested per ASTM C42/C42M.


Document: 

SP364_5

Date: 

December 1, 2024

Author(s):

Michael Pickett, Daniel Richey, Chris Moore, Joshua Umphrey, and Gordon Borne

Publication:

Symposium Papers

Volume:

364

Abstract:

Reinforced concrete sections have typically been the most used material for hardened protective construction due to their mass and the ductility provided by the reinforcement. The additional mass of these sections reduces deflections and increases dampening, which reduces vibrations. Even for the occasional occurrence of hardened steel structures, the foundation is comprised of reinforced concrete. Reinforced concrete structures are hardened for a multitude of reasons. The most common include antiterrorism, force protection, equivalent protection for quantity distance arc violations, personnel protection, prevention of prompt propagation, asset protection, and elastic response during repeated intentional detonations. Many of the structures in the United States (US) used by the Department of Defense (DoD), to accommodate a rapid increase in production and storage of explosives were built during World War II (1941-1945). Facilities used for explosives production, maintenance, research and development (R&D), demolition, testing, and training are commonly referred to as Explosives Operating Locations (EOLs). This puts the average age of many of these facilities close to 80 years-old, which is past their originally intended service life. This paper presents a structural health and visual inspection (SHVI) technique developed by the U.S. Army Corps of Engineers (USACE) Facilities Explosives Safety Mandatory Center of Expertise (FES MCX), the University of Oklahoma, and the Engineering Research and Development Center (ERDC) Geotechnical and Structures Laboratory (GSL) for the inspection of reinforced concrete Explosives Operations Location (EOL) facilities and live-fire training facilities [9]. This inspection process has been utilized to inspect over 1500 structures across multiple countries over the last decade and aid DoD installations in planning and budgeting for necessary repairs and future recapitalization priorities. This work does not include application to anti-terrorism or force protection in hardened structures for conventional weapon effects. This process has also been modified for use in live-fire training operations in concrete facilities and coupled with analyses to determine facility adequacy for explosives operations with desired charge weights, based on the given facility’s current structural health rating and its analyzed ability to remain elastic during repeated intentional detonations. The FES MCX partners with ERDC for concrete coring, materials analysis, and testing of samples to determine the estimated remaining service life of concrete structures based on the carbonation front of cored samples determined by the carbonation tests in relationship to the steel reinforcement. Examples of historical application will be given, and details provided on how these methods can lead to improved life-cycle cost for concrete structures and paired with design development criteria for optimal results.

DOI:

10.14359/51745457


Document: 

SP364_6

Date: 

December 1, 2024

Author(s):

Josh Umphrey, Chris Moore, Daniel Richey, Gordon Borne, and Michael Pickett

Publication:

Symposium Papers

Volume:

364

Abstract:

Reinforced concrete sections have typically been the most used material for hardened protective construction due to their mass and the ductility provided by the reinforcement. The additional mass of these sections reduces deflections and increases dampening, which reduces vibrations. Even for the occasional occurrence of hardened steel structures, the foundation is comprised of reinforced concrete. Reinforced concrete structures are hardened for a multitude of reasons. Some of the most common include antiterrorism, force protection, equivalent protection for quantity distance arc violations, personnel protection, prevention of prompt propagation, asset protection, and elastic response during repeated detonations. Many of the structures used in the Department of Defense (DoD), for these purposes, were built in the United States (US) during the World War II era (1941-1945) for a rapid increase in production and storage of explosives. This puts the average age of many of these facilities at close to 80 years-old, which is past their originally intended service life. This paper presents a structural health and visual inspection technique developed by the U.S. Army Corps of Engineers (USACE) Engineering and Support Center Huntsville (CEHNC) Facilities Explosives Safety Mandatory Center of Expertise (FES MCX) and the Engineering Research and Development Center (ERDC) Geotechnical and Structures Laboratory (GSL) for the inspection of reinforced concrete earth covered magazines (ECMs) [9]. This inspection process has been utilized to inspect over 1500 earth covered magazines across multiple countries over the last decade and aid DoD installations in planning and budgeting for concrete repairs and ECM replacements. The CEHNC FES MCX partners with ERDC for concrete coring and testing of samples to determine the estimated remaining service life of concrete structures based on the carbonation front of cored samples determined by the carbonation tests in relationship to the steel reinforcement. Examples of historical application will be given, and details provided on how these methods can lead to improved life-cycle cost and decision making.

DOI:

10.14359/51745458


Document: 

CI4612DCC

Date: 

December 1, 2024

Publication:

Concrete International

Volume:

46

Issue:

12

Abstract:

When used properly, product samples can inspire and motivate an owner or decision-maker to choose a construction team and its products. Effective samples can tell the story of the substrate being addressed, the systems as they will be installed, and the anticipated finished outcome of the proposed project. They can also demonstrate the team’s craftsmanship and attention to detail.


Document: 

SP-363-1

Date: 

July 1, 2024

Author(s):

Raid S. Alrashidi, Rami Zamzami, Megan S. Voss, Daniel J. Alabi, Christopher C. Ferraro, H. R. Hamilton, Joel B. Harley, and Kyle A. Riding

Publication:

Symposium Papers

Volume:

363

Abstract:

The presence of chloride ions is one of the most widespread causes of corrosion initiation in reinforcing steel in concrete. Trace chlorides present in cementitious materials or admixtures typically result in very low fresh chloride contents in normal-strength concrete that do not present a danger of corrosion. UHPC mixture designs, however, use much higher dosages of cementitious materials and admixtures that can result in non-negligible total fresh chloride contents. These high chloride values are likely to occur more frequently in the future as more UHPC mixtures are made with locally available materials and alternative cementitious materials and may result in concrete mixtures failing to meet specifications for fresh chloride content limits that are based on mixture proportions used in normal-strength concrete mixtures. UHPC and normal concrete samples were made without fibers and with increasing levels of internally admixed chlorides for four different levels of strength to determine chloride thresholds for internally added chlorides. The chloride threshold for fresh concrete was measured using a slightly modified version of the accelerated test EN 480-14. The water-soluble and acid-soluble chloride ion content of UHPC mixtures tested were measured according to ASTM C1218 and Florida Method FM 5-516 to determine the bound chlorides and fresh chloride limits for corrosion. The results demonstrate that the UHPC had ~ 25% higher chloride threshold than the control mixture when measured as an absolute content per unit volume of concrete. When the UHPC chloride content is normalized by mass of cementitious material, it was found that the amount needed to initiate corrosion may be lower than fresh chloride limits given in ACI-318 and ACI 222. Therefore, the ACI-318 water-soluble chloride limits as a % by mass of cementitious materials were found to be non-conservative for the two of the UHPC mixtures tested and should be re-examined for UHPC.

DOI:

10.14359/51742104


12345...>>

Results Per Page 





ABOUT THE INTERNATIONAL CONCRETE ABSTRACTS PORTAL

  • The International Concrete Abstracts Portal is an ACI led collaboration with leading technical organizations from within the international concrete industry and offers the most comprehensive collection of published concrete abstracts.

Edit Module Settings to define Page Content Reviewer