355.2-07 Qualification of Post-Installed Mechanical Anchors in Concrete & Commentary

Currency Display

Your Price:$ 67.50 USD

Member Price: $ 42.00 USD

Save $ 25.50 USD, Become a Member

Choose Product Language

Choose Product Units


Choose Product Format


Notes/Preview

**A newer version of this document exists**

NEW VERSION

 

Description

ACI 355.2 prescribes testing programs and evaluation requirements for post-installed mechanical anchors intended for use in concrete under the design provisions of ACI 318. Criteria are prescribed for determining whether anchors are acceptable for use in uncracked concrete only, or in cracked as well as uncracked concrete. Performance categories for anchors are established, as are the criteria for assigning anchors to each category. The anchor performance categories are used by ACI 318 to assign capacity reduction factors and other design parameters.

Keywords: anchors; cracked concrete; expansion anchors; fasteners; mechanical anchors; post-installed anchors; undercut anchors.

 

Document Details

Author: ACI Committee 355

Publication Year: 2007

Pages: 35

ISBN: 9780870312472

Categories: Anchors

Formats: PDF

This document is Historical

Table of Contents

Chapter 1—Scope

Chapter 2—Definitions and notation

2.1—Definitions

2.2—Notation

Chapter 3—Significance and use

Chapter 4—General requirements

4.1—Testing sequence

4.2—Test samples

4.3—Testing by independent testing and evaluation agency and by manufacturer

4.4—Changes to product

Chapter 5—Requirements for test specimens,installing anchors, and conducting tests

5.1—Concrete for test members

5.2—Anchor installation

5.3—Test methods

5.4—Tests in cracked concrete

5.5—General requirements for anchor behavior

Chapter 6—Requirements for anchor identification

6.1—Determination of critical characteristics of anchors

6.2—Specification of critical characteristics of anchors

6.3—Verification of conformance to drawings and specifications

Chapter 7—Reference tests

7.1—Purpose

7.2—Reference tension tests for single anchors without spacing and edge effects (Table 4.1, Tests 1 and 2, or Table 4.2, Tests 1, 2, 3, and 4)

7.3—Required calculations using results of reference tests

Chapter 8—Reliability tests

8.1—Purpose

8.2—Reliability tests using reduced installation effort (Table 4.1, Test 3, and Table 4.2, Test 5)

8.3—Reliability in low-strength concrete with large drill bit (Table 4.1, Test 4, and Table 4.2, Test 6)

8.4—Reliability in high-strength concrete with small drill bit (Table 4.1, Test 5, and Table 4.2, Test 7)

8.5—Reliability under repeated load (Table 4.1, Test 6)

8.6—Reliability in cracked concrete where crack width is cycled (Table 4.2, Test 8)

Chapter 9—Service-condition tests

9.1—Purpose

9.2—Service-condition tension test with single anchor and with two edges (corner) (Table 4.1, Test 7, and Table 4.2, Test 9)

9.3—Service-condition test at minimum edge distance and minimum spacing (Table 4.1, Test 8, and Table 4.2, Test 10)

9.4—Service-condition shear test for single anchors without spacing and edge effects (Table 4.1, Test 9,and Table 4.2, Test 11)

9.5—Service-condition, simulated seismic tension tests (Table 4.2, Test 12)

9.6—Service-condition, simulated seismic shear tests (Table 4.2, Test 13)

Chapter 10—Establishing anchor categories

Chapter 11—Presenting anchor data

11.1—Data analysis

11.2—Format of data sheet

11.3—General requirements

11.4—Contents of evaluation report

Chapter 12—Requirements for independent testing and evaluation agency

Chapter 13—References

13.1—Referenced standards

MANDATORY APPENDIXES

Appendix A1—Requirements for normalization of results

A1.1—Normalization of capacities to take account of concrete and steel strengths

A1.2—Concrete breakout or splitting failure

A1.3—Pullout and pull-through failure

A1.4—Steel failure

Appendix A2—Requirements for establishing characteristic capacities

A2.1—Scope

A2.2—Procedure

Appendix A3—Requirements for test members

A3.1—Tests in uncracked concrete

A3.2—Tests in cracked concrete

A3.3—Casting and curing of test members

COMMENTARY

Chapter R1—Scope

Chapter R2—Definitions and notation

R2.1—Definitions

R2.2—Notation

Chapter R3—Significance and use

Chapter R4—General requirements

R4.1—Testing sequence

R4.2—Test samples

Chapter R5—Requirements for test specimens, installing anchors, and conducting tests

R5.1—Concrete for test members

R5.2—Anchor installation

R5.4—Tests in cracked concrete

R5.5—General requirements for anchor behavior

Chapter R6—Requirements for anchor identification

R6.3—Verification of conformance to drawings and specifications

Chapter R7—Reference tests

R7.2—Reference tension tests for single anchors without spacing and edge effects (Table 4.1, Tests 1 and 2, or Table 4.2, Tests 1, 2, 3, and 4)

R7.3—Required calculations using results of reference tests

Chapter R8—Reliability tests

R8.2—Reliability tests using reduced installation effort (Table 4.1, Test 3, and Table 4.2, Test 5)

R8.3—Reliability in low-strength concrete with large drill bit (Table 4.1, Test 4, and Table 4.2, Test 6)

R8.4—Reliability in high-strength concrete with small drill bit (Table 4.1, Test 5, and Table 4.2, Test 7)

R8.5—Reliability under repeated load (Table 4.1, Test 6)

R8.6—Reliability in cracked concrete where crack width is cycled (Table 4.2, Test 8)

Chapter R9—Service-condition tests

R9.2—Service-condition tension test with single anchor and with two edges (corner) (Table 4.1, Test 7, and Table 4.2, Test 9)

R9.3—Service-condition test at minimum edge distance and minimum spacing (Table 4.1, Test 8, and Table 4.2, Test 10)

R9.4—Service-condition shear test for single anchors without spacing and edge effects (Table 4.1, Test 9, and Table 4.2, Test 11)

R9.5—Service-condition, simulated seismic tension tests (Table 4.2, Test 12)

R9.6—Service-condition, simulated seismic shear tests (Table 4.2, Test 13)

Chapter R11—Presenting anchor data

Chapter R13—References

R13.1—Cited references

Appendix RA1—Requirements for normalization of results

RA1.2—Concrete breakout or splitting failure

RA1.3—Pullout and pull-through failure Appendix RA3—Requirements for test members

RA3.2—Tests in cracked concrete

EXAMPLE EVALUATION OF A WEDGE-TYPE ANCHOR IN UNCRACKED CONCRETE

E1—Anchor specifications

E2—Test results

E3—Evaluation

E3.1—General

E3.2—Reference tests in uncracked low-strength concrete

E3.3—Reference tests in uncracked high-strength concrete

E3.4—Reliability tests, reduced installation effort

E3.5—Reliability tests, large hole diameter

E3.6—Reliability tests, small hole diameter

E3.7—Reliability tests, repeated load

E3.8—Service-condition tests, corner test

E3.9—Service-condition tests, minimum edge distance and spacing

E3.10—Service-condition tests, shear tests

E4—Establishing anchor category

E5—Report of anchor data

ERRATA INFO

Any applicable errata are included with individual documents at the time of purchase. Errata are not included for collections or sets of documents such as the ACI Collection. For a listing of and access to all product errata, visit the Errata page.

Return/Exchange Policy

Printed / Hard Copy Products: The full and complete returned product will be accepted if returned within 60 days of receipt and in salable condition. A 20% service charge applies. Return shipping fees are the customer’s responsibility.

Electronic /Downloaded Products & Online Learning Courses: These items are not eligible for return.

Subscriptions These items are not eligible for return.

Exchanges: Contact ACI’s Customer Services Department for options (+1.248.848.3800 – ACICustomerService@concrete.org).