ACI PRC-304.3-96: Heavyweight Concrete: Measuring, Mixing, Transporting, and Placing (Reapproved 2004)

Currency Display

Your Price:$ 31.50 USD

Member Price: $ 21.00 USD

Save $ 10.50 USD, Become a Member

Choose Product Language

Choose Product Units


Choose Product Format


Notes/Preview

**A newer version of this document exists**

NEW VERSION

 

Description

Presents recommended methods and procedures for measuring, mixing, transporting, and placing heavyweight concretes that are used principally for radiation shielding in nuclear construction. Also covered are recommendations on cement, heavyweight aggregates, water, and admixtures. Mixture proportioning of heavyweight concrete is discussed. Recommendations for preplaced-aggregate heavyweight concrete are also included, together with suitable grout proportions. Mixing equipment, form construction, placing procedures, and methods of consolidation are described. Quality control, inspection, and testing are emphasized, and a list of references is included.

Keywords: admixtures; aggregates; barite; cements; concrete construction; concretes; consolidation; construction equipment; conveying; density (mass/volume); formwork (construction); grout; heavyweight aggregates; heavyweight concretes; ilmenite; limonite; magnetite; mass concrete; materials handling; mix proportioning; mixing; placing; quality control; preplaced-aggregate concrete; radiation shielding; segregation.

 

Document Details

Author: ACI Committee 304

Publication Year: 2002

Pages: 8

ISBN: 9780870313165

Categories: Placing

Formats: PDF

This document is Historical

Table of Contents

GENERAL CONSIDERATIONS

Chapter 2: MATERIALS

2.1 Cement

2.2 Aggregate

2.3 Mixing water

2.4 Admixtures

2.5 Proprietary premixed mortar

CONCRETE CHARACTERISTICS

3.1 Physical properties

3.2 Mixture proportioning

EQUIPMENT

FORMWORK

5.1 Conventional method

5.2 Preplaced aggregate method

PLACEMENT

6.1 Conventional method

6.2 Preplaced aggregate method

QUALITY CONTROL

7.1 Samples and tests

7.2 Cement

7.3 Aggregate

7.4 Admixtures

7.5 Control tests

7.6 Inspection

REFERENCES

8.1 Specified and/or recommended references

8.2 Citied References

ERRATA INFO

Any applicable errata are included with individual documents at the time of purchase. Errata are not included for collections or sets of documents such as the ACI Collection. For a listing of and access to all product errata, visit the Errata page.

Return/Exchange Policy

Printed / Hard Copy Products: The full and complete returned product will be accepted if returned within 60 days of receipt and in salable condition. A 20% service charge applies. Return shipping fees are the customer’s responsibility.

Electronic /Downloaded Products & Online Learning Courses: These items are not eligible for return.

Subscriptions These items are not eligible for return.

Exchanges: Contact ACI’s Customer Services Department for options (+1.248.848.3800 – ACICustomerService@concrete.org).