Email Address is required Invalid Email Address
In today’s market, it is imperative to be knowledgeable and have an edge over the competition. ACI members have it…they are engaged, informed, and stay up to date by taking advantage of benefits that ACI membership provides them.
Read more about membership
Learn More
Become an ACI Member
Founded in 1904 and headquartered in Farmington Hills, Michigan, USA, the American Concrete Institute is a leading authority and resource worldwide for the development, dissemination, and adoption of its consensus-based standards, technical resources, educational programs, and proven expertise for individuals and organizations involved in concrete design, construction, and materials, who share a commitment to pursuing the best use of concrete.
Staff Directory
ACI World Headquarters 38800 Country Club Dr. Farmington Hills, MI 48331-3439 USA Phone: 1.248.848.3800 Fax: 1.248.848.3701
ACI Middle East Regional Office Second Floor, Office #207 The Offices 2 Building, One Central Dubai World Trade Center Complex Dubai, UAE Phone: +971.4.516.3208 & 3209
ACI Resource Center Southern California Midwest Mid Atlantic
Feedback via Email Phone: 1.248.848.3800
ACI Global Home Middle East Region Portal Western Europe Region Portal
Home > Publications > International Concrete Abstracts Portal
The International Concrete Abstracts Portal is an ACI led collaboration with leading technical organizations from within the international concrete industry and offers the most comprehensive collection of published concrete abstracts.
Showing 1-5 of 144 Abstracts search results
Document:
SP-361_06
Date:
March 1, 2024
Author(s):
Michelle L. Hendrickson, Christine A. Langton, and Joan Q. Wu
Publication:
Symposium Papers
Volume:
361
Abstract:
Sixty percent of the nation's highly toxic and radioactive mixed wastes are stored at Hanford in 177 deteriorating underground storage tanks. To close or remove these storage tanks from service and place them in a condition that is protective of human health and the environment, the tanks must be physically stabilized to prevent subsidence once wastes have been retrieved. Remaining residual liquid waste in the tanks that cannot be removed must be solidified and the solid wastes encapsulated to meet the Nuclear Regulatory Commission, Department of Energy, Environmental Protection Agency, and the State of Washington requirements. The Department of Energy has developed cementitious flowable concretes to restrict access and provide chemical stabilization for radionuclides. Formulation, laboratory, and field testing for application at Hanford began with flowable, self-leveling structural and non-structural fills. A slump flow equal to or greater than 610 mm, 0% bleed water, and 0.1% (by volume) shrinkage measurements were key parameters guiding reformulation efforts that resulted in highly flowable, self-consolidating concretes that met Hanford 241-C Tank closure short- and long-term regulatory and engineering performance requirements.
DOI:
10.14359/51740608
SP-360_25
Francesca Ceroni, Alberto Balsamo, Marco Di Ludovico
360
Masonry structures are very sensitive to out-of-plane mechanisms under horizontal actions. A common traditional technique to avoid or mitigate the activation of these mechanisms is represented by injected anchors made of steel bars aimed to improve the connections between orthogonal masonry walls or between floors and masonry walls. The bars are usually embedded in the masonry by means of cement-based grout in holes realized inside the elements to be connected. Recently, an increased interest has developed in the scientific community about the use of Fibre Reinforced Plastic (FRP) bars as alternative to the steel ones for injected anchors, mainly because of their high tensile strength and inertia to corrosion, which can give them high durability, in addition to the use of high-performance grouts. The paper reports the results of experimental pull-out tests realized by the Authors on several types of FRP bars used as injected anchors in small masonry specimens made of yellow tuff blocks. A hydraulic lime and pozzolana-based grout is used to fix the bars in holes realized in the masonry specimens along an embedded length of 250 mm. The set-up is realized in order to apply pure tension to the bars and shear stresses along the bar-grout and the grout-masonry interfaces. The results are analysed in terms of maximum pull-out forces, failure modes and force-displacement relations in order to evidence the global performance of each tested system, especially in relation with the diameter and the surface treatment of the bars. Some comparisons with literature formulation for predicting the pull-out force are developed too.
10.14359/51740637
SP-345_12
February 1, 2021
Xingxing Zou, Chris Moore, and Lesley H. Sneed
345
Externally bonded (EB) steel reinforced grout (SRG) composites have the potential to improve the flexural and shear performance of existing concrete and masonry structural members. However, one of the most commonly observed failure modes of SRG-strengthened structures is due to composite debonding, which reduces composite action and limits the SRG contribution to the member load-carrying capacity. This study investigated an endanchorage system for SRG strips bonded to a concrete substrate. The end anchorage was achieved by embedding the ends of the steel cords into the substrate. Nineteen single-lap direct shear specimens with varying composite bonded lengths and anchor binder materials were tested to study the effectiveness of the end-anchorage on the bond performance. For specimens with relatively long bonded length, the end-anchorage slightly improved the performance in terms of peak load achieved before detachment of the bonded region. Anchored specimens with long bonded length showed notable post-detachment behavior. Anchored specimens with epoxy resin achieved load levels significantly higher than the peak load before composite detachment occurred. For specimens with relatively short bonded length, the end-anchorage provided a notable increase in peak load and global slip at composite detachment. A generic load response was proposed for SRG-concrete joints with end anchors.
10.14359/51731578
SP-345_16
Gianmarco de Felice, Stefano De Santis, and Pietro Meriggi
In 2017, the Rilem Technical Committee 250-CSM coordinated a Round Robin initiative, in which 19 research institutions tested 28 Fabric Reinforced Cementitious Matrix (FRCM) composites, with the support of 11 industrial partners. Two years after the publication of the first papers on the results of this wide investigation, it is still worth further analysing its outcomes to highlight the fundamental properties of mortar-based reinforcements and give an overview of the various available fabrics and matrices, which are currently used in structural rehabilitation activities. Equally, a better understanding still needs to be gained on the causes of the variability observed in test results. These include the quasibrittle behaviour of the inorganic matrix and its sensitivity to manufacturing, curing and handling. Test implementation, such as gripping method and measuring techniques, also plays a crucial role in the reliability and repeatability of experimental outcomes.
10.14359/51731582
SP341
July 17, 2020
341
ACI Committees 441 – Reinforced Concrete Columns and 341A – Earthquake-Resistant Concrete Bridge Columns, Mohamed A. ElGawady Columns are crucial structural elements in buildings and bridges. This Special Publication of the American Concrete Institute Committees 441 (Reinforced Concrete Columns) and 341A (Earthquake-Resistant Concrete Bridge Columns) presents the state-of-the-art on the structural performance of innovative bridge columns. The performance of columns incorporating high-performance materials such as ultra-high-performance concrete (UHPC), engineered cementitious composite (ECC), high-strength concrete, high-strength steel, and shape memory alloys is presented in this document. These materials are used in combination with conventional or advanced construction systems, such as using grouted rebar couplers, multi-hinge, and cross spirals. Such a combination improves the resiliency of reinforced concrete columns against natural and man-made disasters such as earthquakes and blast.
10.14359/51727058
Results Per Page 5 10 15 20 25 50 100